Braiding Shielded Flex LSZH CY Control Cable

Product Description

Copper Wire Braiding Shielded LSZH CY Control Cable

Overview

ENGELEC's flex LSZH CY control cables, known as tinned copper wire braiding screened LSZH flexible cables or by their European designation HSLHCH (LSZH sheathed), are used as interconnecting cables for measurement, control or regulation in control equipment for assembly and production lines, conveyors, and computer units. 

They are typically used in applications requiring interference-free transmission due to their multi-core flex, tinned copper wire braid (TCWB), and polyethylene terephthalate (PET) separator, which protect it from external electromagnetic influences which could degrade accurate signal transmission. The CY cable's TCWB and PET also provide protection against light mechanical stress.

These cables are suitable for flexible use when temporarily moved without tensile stress. ENGELEC flex LSZH CY control cables can be used outdoors when protected against direct sunlight, and in dry or moist conditions (including oil-water mixtures) indoors.

These screened flexible multi-core LSZH CY control cables have a voltage rating of 450/750V.

Product Description
Construction

Conductor

Class 5, Annealed plain copper, sizes: 1.5mm⊃2;,2.5mm⊃2;, 4mm⊃2; & 6mm⊃2; to BS 6360

Insulation

90˚C LSZH(low smoke zero halogen), EN 50525

Binder

Transparant PET tape

Colour code


According to EN50525,

Screen

Tinned Copper Wire Braiding,  shielding coverage > 80%

Bedding Sheath

90˚C LSZH(low smoke zero halogen), EN 50525  

Outer sheath

90˚C LSZH(low smoke zero halogen), EN 50525

Sheath colour

Gray or Transparant

Mechanical and Electrical Properties  

*  Operating temperature    : -20˚C up to + 100˚C( fixed installation) ; -10˚C to +90˚C( flexed operation ).

*  Minimum bending radius :  12 x overall diameter.

Conductor Area Size

mm2

1.5

2.5

4

6

Conductor resistance max

ohm/km

13.3

7.98

4.95

3.3

Insulation resistance min

Mohm/km

25

25

25

25

Current carrying capacity at 30˚C  in air

A

24

32

42

54

                                 in conduct

A

15

18

26

34

Braided shielding coverage

%

>80

>80

>80

>80

Voltage drop

mV/A/m

25

15

9.5

6.4

AC voltage wthstand test

V

2500

2500

2500

2500

Rated voltage max

V

450/750

450/750

450/750

450/750

Dimension Parameter

Engelec Cable Part Number

No.of Cores

Nominal Conductor CSA

Nominal Thickness

of Insulation

Nominal Thickness

of bedding

Nominal Dia. over Bedding

Thickness

of

shiedling

Nominal Thickness

of Sheath

Nominal Dia. of Cable

Approx. Weight

mm2

mm

mm

mm

mm

mm

mm

kg/km

EECYY3C15

3

1.5

0.6

0.5

6.6

0.12

0.7

8.2

90

EECYY3C25

3

2.5

0.7

0.5

7.9

0.12

0.8

9.7

136

EECYY3C40

3

4

0.8

0.6

9.6

0.12

0.9

11.6

210

EECYY3C60

3

6

0.8

0.6

10.7

0.12

1

12.9

285

EECYY4C15

4

1.5

0.6

0.5

7.3

0.12

0.7

8.9

114

EECYY4C25

4

2.5

0.7

0.5

8.8

0.12

0.8

10.6

173

EECYY4C40

4

4

0.8

0.6

10.6

0.12

1

12.8

260

EECYY4C60

4

6

0.8

0.6

11.6

0.12

1.1

14

358

EECYY5C15

5

1.5

0.6

0.5

8

0.12

0.8

9.8

142

EECYY5C25

5

2.5

0.7

0.5

9.7

0.12

0.9

11.7

216

EECYY5C40

5

4

0.8

0.6

11.5

0.12

1

13.7

325

EECYY5C60

5

6

0.8

0.6

12.8

0.12

1.1

15.2

449

EECYY7C15

7

1.5

0.6

0.5

8.8

0.12

0.8

10.6

180

EECYY7C25

7

2.5

0.7

0.5

10.6

0.12

1

12.8

283

EECYY7C40

7

4

0.8

0.6

12.6

0.12

1.1

15

420

EECYY7C60

7

6

0.8

0.6

14.1

0.12

1.2

16.7

550

EECYY12C15

12

1.5

0.6

0.6

11.2

0.12

1.1

13.6

307

EECYY12C25

12

2.5

0.7

0.7

14.7

0.12

1.2

17.3

450

EECYY12C40

12

4

0.8

0.8

17.4

0.12

1.4

20.4

650

EECYY12C60

12

6

0.8

0.8

19.4

0.12

1.4

22.4

860

Test and Standard

Professional and strict lab test after production.

CY PVC (YSLCY) Control Cable is tested by the standard of 

VDE 0207-363-3, VDE 0285-525-2-51, VDE 0285-525-1, VDE 0285-525-2-11, VDE 0482-332-1-2, VDE 819-102 (TM54) 
Flame Retardant according to IEC 60332-1-2


Screened Bedded LSZH (HSLHCH) Cable is tested by the standard of 

VDE 0295, VDE 0207-303-7, VDE 0293-308, VDE 0285-525-2-51, VDE 0285-525-3-11, VDE 0482-332-1-2,  VDE 0819-102 
Flame Retardant according to IEC 60332-3-24, IEC 60332-1-2 Low Smoke Density / Halogen free according to IEC 61034-2, IEC 60754-1/2


CY LSZH (HSLCH) Control Cable is tested by the standard of 

VDE 0207-303-7, VDE 0285-525-1, VDE 0285-525-2-51,  VDE 0482-332-1-2, VDE 0482-332-3-24, VDE 0482-754-1/2, VDE 0482-1034-2 
Flame Retardant according to IEC 60332-3-24, IEC 60332-1-2 Low Smoke Density / Halogen free according to IEC 61034-2, IEC 60754-1/2